e-ISSN: 2394-2967
logo

British Journal of Medical and Health Research

Published

Wear Resistance and Long-Term Retention of Novaloc Versus Traditional Ball And Socket Implant Attachments Retaining Mandibular Complete Overdenture (In Vitro Study)

Published in October 2022 Issue 10 (Vol. 9, Issue 10, 2022)

Wear Resistance and Long-Term Retention of Novaloc Versus Traditional Ball And Socket Implant Attachments Retaining Mandibular Complete Overdenture (In Vitro Study) - Issue cover

Abstract

ABSTRACT This study compares the wear changes and retention between two stud attachments “Ball” and “Novaloc” used for implanted supported mandibular overdenture. Two epoxy resin models represented completely edentulous patients were duplicated from an educational cast and prepared to receive two implant analogues in the canine area. Two different attachment systems were used: the first one was Ball attachment with a metal housing of gold insert, the second one was Novaloc with a PEEK matrix & insert. They were divided randomly into two groups. Two overdentures were fabricated for each group. The pick-up proceeded as conventional methods. Robota simulator applied multiple cycles mimicking the insertion and removal of the overdentures at the baseline, 500 cycles, 1000 cycles, 1500 cycles and 2000 cycles. Digital microscope evaluated the wear behavior of each attachment during these different cycles. Attachments retention was measured using universal testing machine. Wear changes comparison of both groups revealed that Novaloc group was significantly higher than Ball group between baseline and 2000 cycles. Regarding retention, comparison between both groups revealed that retention Novaloc group was significantly lower (P<0.05) than Ball group at baseline, 1000 cycles, 1500 cycles & 2000 cycles. The rate of wear was higher in Novaloc attachment which had PEEK Inserts than those of ball attachments with its gold precious alloy inserts. Regarding retention of both attachments, the Ball attachments had a significant higher initial and final retention values than the Novaloc attachments. Keywords: Novaloc attachment, Ball attachment, Retention, Wear changes

Authors (4)

Hatem Magdi

B.D.S, Faculty of Dentistry, C...

View all publications →

Maha Wagdy

Professor of Oral and Maxillof...

View all publications →

Ahmed Fayad

Professor, of Oral and Maxillo...

View all publications →

Eatemad Rekaby

Professor of Oral and Maxillof...

View all publications →

Download Article

PDF

Best for printing and citation

File size: 0.0 MB
Format: PDF

Download Article

PDF

Best for printing and citation

File size: 0.0 MB
Format: PDF

Article Information

BJMHR0910004

BJMHR-09-000004

2022-10-01

Article Impact

Views:3,371
Downloads:2,480
scite_
PlumX Metrics Badge

How to Cite

APA
MLA
Chicago
Harvard
Vancouver
IEEE
ACM
ACS
ABNT
Turabian
RIS (EndNote/Zotero/Mendeley)
BibTeX

Magdi & Wagdy & Fayad & Rekaby (2022). Wear Resistance and Long-Term Retention of Novaloc Versus Traditional Ball And Socket Implant Attachments Retaining Mandibular Complete Overdenture (In Vitro Study). British Journal of Medical and Health Research, 9(10), xx-xx. DOI:https://doi.org/10.5281/zenodo.7270396

Article Actions