e-ISSN: 2394-2967
logo

British Journal of Medical and Health Research

Published

REMOVABLE OVERDENTURE VERSUS FIXED BRIDGE FABRICATED ON ALL-ON-4 IMPLANTS USING CAD/CAM TECHNOLOGY (STRAIN GAUGE ANALYSIS)

Published in December 2021 Issue 12 (Vol. 8, Issue 12, 2021)

REMOVABLE OVERDENTURE VERSUS FIXED BRIDGE FABRICATED ON ALL-ON-4 IMPLANTS USING CAD/CAM TECHNOLOGY (STRAIN GAUGE ANALYSIS) - Issue cover

Abstract

Statement of the problem. Assessing the effects on maxilla when using fixed vs. removable prosthesis on All-On-4® protocol. This in-vitro study was conducted to compare stresses induced on distal implants in the All-On-4® concept between digitally constructed removable overdenture and fixed bridge, using strain gauge analysis. Four dummy implants were placed in their designed locations according to the All-On-4® concept; in a 3D printed completely edentulous maxillary acrylic cast. Multiunit abutments were secured to the implants. Two groups were defined: Group A: The framework was cemented to the four titanium copings over the implants (Fixed bridge). Group B: The same framework was picked up after relief was done and then seated on the ball attachments (Removable overdenture). Stresses were measured using strain gauges installed in their designed sites in the 3D printed cast. Loads of 100N were applied in a vertical and oblique direction on the right molar area. Paired t-test was used to compare between two different load directions within the same group, and unpaired t-test was used to compare between different groups. P-value ≤ 0.05 was statistically significant. Group A with vertical loads (532±9.2) and oblique loads (464±40.3) showed significantly higher stresses on the supporting structures of the distal implants than group B with vertical loads (64 ±7.75) and oblique loads (41.5±2.42). Within group A, higher microstrains were recorded on the distal implants in the loaded side in case of applying vertical loads (532±9.2) than in the case of oblique loads (464±40.3). Also, lower microstrains were recorded in the unloaded side in the case of vertical loads (21.5±2.42) than in oblique loads (43±2.58). Within group B, higher microstrains were recorded in the loaded side in case of applying vertical loads (64±7.75), than in case of oblique loads (41.5±2.42). Also, lower microstrains were recorded in the unloaded side in case of vertical loads (10.5±1.58) than in case of oblique loads (18.5±2.42). Within the limitations of this study, it could be concluded that the distal implants in the fixed bridge suffered higher loads than the removable overdenture.

Authors (5)

Karim Elnabarawy

B.D.S, Faculty of Dentistry, A...

View all publications →

Ahmed Emad Eldin Edamarisy

Lecturer of Prosthodontics, Fa...

View all publications →

Marwa Kothayer Abdel-Hakeem

Associate Professor of Oral an...

View all publications →

Fardos Nabil Rizk

Professor and Head of Prosthod...

View all publications →

Marwa Ezzat Sabet

Professor of Oral and Maxillof...

View all publications →

Download Article

PDF

Best for printing and citation

File size: 0.0 MB
Format: PDF

Download Article

PDF

Best for printing and citation

File size: 0.0 MB
Format: PDF

Article Information

BJMHR0812004

BJMHR-08-000004

2021-12-01

Article Impact

Views:4,828
Downloads:2,109
scite_
PlumX Metrics Badge

How to Cite

Elnabarawy & Ahmed Emad Eldin Edamarisy & Kothayer, M. & Nabil, F. & Ezzat, M. (2021). REMOVABLE OVERDENTURE VERSUS FIXED BRIDGE FABRICATED ON ALL-ON-4 IMPLANTS USING CAD/CAM TECHNOLOGY (STRAIN GAUGE ANALYSIS). British Journal of Medical and Health Research, 8(12), xx-xx. DOI:https://doi.org/10.46624/BJMHR.2021.V8.I12.004

Article Actions